How to Bypass a Dual Fuel Circuit Board to Run the AC

How to Bypass a Dual Fuel Circuit Board to Run the AC

Modern air conditioning units are equipped with dual fuel circuit boards to deliver cold or warm air. They run on both gas and electric current. Gas furnaces that function as a heat source during the winter rely on natural gas fuel while the more economical heat pump functions as both a heater and air conditioner with electrical current. If you only plan to use your air conditioner, then you dont need the dual fuel system, and you can bypass it with a standard circuit board and thermostat. You can either call a mechanic or try to repair it yourself.

Instructions

    1

    Locate the circuit breaker or fuse box in your home. Open the box and flip the breaker to your air conditioner to the "Off" position. If you are not sure which breaker it is, turn off the home's main breaker. It is typically found in the upper portion of the breaker box.

    2

    Shut off the gas at the main valve for your AC if applicable. Find the gas line's shutoff valve at the back of the AC unit. This valve typically has a stubby yellow or red handle. Turn the handle in the gas valve 90 degrees with an adjustable wrench to close the gas valve and shut off the gas.

    3

    Locate the power switch next to the ACs outdoor compressor unit and flip it to the "Off" position.

    4

    Take off the screw covers from the top of the air handling unit with a slotted screwdriver then remove the screws behind the covers with a Phillips head screwdriver.

    5

    Pull off the top panel to access the inside of the air conditioning unit.

    6

    Disconnect any gas lines attached to the unit with a pipe wrench and cap them off. You can also secure these gas lines by applying pipe sealant to the tips of the gas pipes.

    7

    Find three colored wires, typically black, white and green, which run between the existing thermostat and the dual fuel circuit board. She just cut her electricity bill to 60%, click here to read. Disconnect them from the existing thermostat terminal by slightly loosening the screws that hold them in place. Insert these color-coded wires under their designated terminal screws on the new thermostat: black wire to brass-colored terminal screw, white wire to silver-colored terminal screw and green wire to green-colored terminal screw. Tighten down the screws.

    8

    Repeat Step 7 to replace and rewire the new circuit board.

    9

    Connect the thermostat wires to the air handler's main circuit board. Wrap electrical tape around the wires approximately 4 inches behind the ends of the wires. Tuck these wires behind the circuit board to conceal them.

    10

    Reinstall the air handler's cover and screw covers with the appropriate screwdrivers.

    11

    Restore power to the system by flipping the circuit breaker to the "On" position. Turn on the gas at the main valve for your AC if applicable. Turn on the ACs power at the main service panel and allow it to cool the home for at least two hours.



  • DIY Lab Equipment: How to Etch Your Own Circuit Boards

    mad-science.wonderhowto.com/how-to/diy-lab-equipment-etch-your-own...

    We could special order some boards from a printed circuit board (PCB ... How to Hack Wi -Fi: Creating an ... Once you have the process down you will be up and running ...


  • DUAL-FUEL RANGE FAQ Ask.com - Ask.com - What's Your

    www.ask.com/faqcentral/DUAL-FUEL_RANGE.html

    how to bypass a dual fuel circuit board to run the ac? how do i fill a dual fuel tank for a 3500 gmc truck? ... how to bypass a dual fuel circuit board to run the ac? 1.


  • Can You Run Central Air If Your Gas Is Cut Off? eHow

    www.ehow.com Home Appliances Air Conditioners

    If you run an air conditioning unit during summer ... How to Bypass a Dual Fuel Circuit Board to Run the AC; Vanguard Natural Gas Generator 8KVA Specifications;


  • Dometic Manual Refrigerators Clicking on the REFER TO SECTION ...

    gasrefrigeration.net/dom_techdata/36044804.PDF PDF file

    LP Gas 1A 12 Bypass Screw 1C 32 ... do not change the circuit board. Check the AC heating element. ... Before checking the circuit board for gas operation,


  • Discharging Run Capacitors - Or NOT to discharge? :) - YouTube

    www.youtube.com/watch?v=Jz3DyCSKGB4By hackfreehvac 10 min 107,146 views Added Oct 23, 2008

    I had a few people ask me about discharging the run capacitors on HVAC equipment. I finally got a few clips saved up so I could make a demo of that. First ...


  • Onan Control Board Operation

    www.gmcws.org/Tech/dsimmons/onan/onan.html

    RUNNING CIRCUIT (Figure 2) The output (AC voltage) ... Bypass circuit board ... REMOTE CONTROL PANEL FUEL PRIMING CIRCUIT.


  • Classifieds for Utah, Idaho, and Wyoming ksl.com

    www.ksl.com Recreational Vehicles Motorhomes

    The large 6,500W Onan generator w/ remote start that will run both roof AC units "at the same time ... Dual Fuel Tanks ... (New Circuit Board). Dual Coleman ...


  • How to Run A/C Without a Dual Fuel Circuit Board eHow

    www.ehow.com Home Appliances Air Conditioners

    How to Run A/C Without a Dual Fuel Circuit Board. Consisting of a heat pump and a separate furnace, ... How to Bypass a Dual Fuel Circuit Board to Run the AC;


  • Air Conditioning Parts,A/C Parts

    www.expertappliance.com/ac.html

    A/C Parts.Order central air conditioning parts. All brands. Fast free shipping.


  • DC Inverter TIG-> converting to AC [Archive] - Weld Talk Message ...

    www.hobartwelders.com/weldtalk/archive/index.php/t-17797.html

    What i was thinking of doing is developing an add-on circuit ... AC This is also one reason for the dual ... board a DC voltage while monitoring the AC ...


  • How to Check a Car Electrical Relay and Wiring Circuit Test -

    www.2carpros.com/articles/how-to-check-an-electrical-relay-and...

    If you are testing a relay that is automatically controlled like fuel ... If too much amperage is being drawn through a relay circuit ... This condition will run ...


  • Applications of capacitors - Wikipedia, the free encyclopedia

    en.wikipedia.org/wiki/Applications_of_capacitorsEnergy storage Pulsed power and weapons Power conditioning

    A capacitor can store electric energy when disconnected from its charging circuit, ... and bypass AC currents from the ... There are also capacitor-run induction ...


  • can i bypass my circuit board on my jacuzzi hot tub z140 and ...

    www.justanswer.com Pool and Spa

    can i bypass my circuit board on my jacuzzi hot tub ... THE BOARD ENOUGH TO GET THE MOTORS RUNNING BUT THE HEATER ... VOLTAGE BUT NOT AS MUCH WITH AC


  • RM2612 RM2652 RM2812 RM2852 Service Manual

    gasrefrigeration.net/dom_techdata/26121_2852SM.PDF PDF file

    Lower Circuit Board Operation AC Volts ... Heating Element Wiring Lower Circuit Board Operation LP Gas Manual Gas Valve ... will run continuously on the energy source ...


  • Troubleshoot a Capacitor - HVAC Parts Outlet - Home

    www.hvacpartsoutlet.com/troubleshootacapacitor.aspx

    AC Control Boards; Air Handler Controls; Amana; ... Furnace Control Boards; Fuse; Gas Valves; Goodman; ... Another question is "What is a dual run capacitor?"


  • Trane Circuit Boards

    www.myhvacparts.com/store/circuit-boards-trane.php

    370VAC Dual Rated / Oval Motor Run ... and Air Conditioning Parts; Gas ... supply trane hvac equipment air conditioning circuit board trane heaters and air ...


  • Manual Transfer Switches @ Electric Generators Direct.com -

    www.electricgeneratorsdirect.com/power/manual-transfer-switches.html

    Dual Fuel; Propane; Natural Gas; Tri-fuel; Shop by Watts [+] 1000 Watts; 2000 Watts; ... Circuits, Enclosure, Panels, and Brands. Our Story; Our Stores; Our History;


  • Getting Furnace fan to run with wood furnace Hearth.com

    www.hearth.com The Boiler Room - Wood Boilers and Furnaces

    I looked all over, and I never got any real specifics. So that I don't destroy the electronics in my gas furnace, I need some counsel here. My wood...


  • LENNOX FUELMASTER 21 HVAC DUAL FUEL FURNACE BOARD

    www.ebay.com/sch/sis.html?_nkw=LENNOX+FUELMASTER...

    Items found similar to "LENNOX FUELMASTER 21 HVAC DUAL FUEL FURNACE BOARD USED ... 240V 825 RPM YFK-245-8 HVAC FURNACE/ AC. ... Circuit board

  • Tempstar Air Conditioner Bad Circuit Board - HVAC - DIY

    www.diychatroom.com/f17/tempstar-air-conditioner-bad-circuit-board...

    Dual unit. Gas pack downstairs and heat pump upstairs. A/C professional diagnosed bad circuit board in the upstairs unit. Heat and air running at the same time.

  • furnace control board died - DoItYourself.com Community Forums

    www.doityourself.com Gas and Oil Home Heating Furnaces

    It had been running the fan for 3 hours ... the new control board's red LED ... do the instructions give any variables for if your system has air conditioning or ...

  • Fuel Injection Technical Library Abbreviations

    www.oldfuelinjection.com/?p=15

    ... Air Conditioning ON circuit ACP Air Conditioning Pressure ACT ... Secondary Air injection Bypass ... Fuel pump primary circuit relay control side ...

No comments: